F. H. Richardson's bluebook of projection (1935)

Record Details:

Something wrong or inaccurate about this page? Let us Know!

Thanks for helping us continually improve the quality of the Lantern search engine for all of our users! We have millions of scanned pages, so user reports are incredibly helpful for us to identify places where we can improve and update the metadata.

Please describe the issue below, and click "Submit" to send your comments to our team! If you'd prefer, you can also send us an email to mhdl@commarts.wisc.edu with your comments.




We use Optical Character Recognition (OCR) during our scanning and processing workflow to make the content of each page searchable. You can view the automatically generated text below as well as copy and paste individual pieces of text to quote in your own work.

Text recognition is never 100% accurate. Many parts of the scanned page may not be reflected in the OCR text output, including: images, page layout, certain fonts or handwriting.

THE PROJECTION ROOM 257 Rheostat Room (48) If rheostats that are not units of the motor generator equipment are employed to control projection current, they should be located in a separate, thoroughly ventilated room adjacent to the main room. (49) This is necessary not only for the comfort and health of the projectionists, but also as a matter of safety. Hot rheostat grids or coils, and inflammable film, are dangerous combinations in the same room. Motor Generator Room (50) Motor generator sets should be located in an airy room adjoining the main projection room. There should be sufficient free space around them to enable all necessary work to be carried forward with reasonable convenience. (51) The generator room should be sound-proofed. (52) Never locate storage batteries in the same room with motor generator sets or other electrical equipment. Battery Room (53) Storage batteries should be located in a separate room connecting with the projection room. When charging, batteries give off gases that are injurious if breathed in considerable quantities, and likewise do serious damage to the insulation of electrical equipment nearby. These gases must be exhausted to the outer air as fast as they form. (54) Wood floors in battery rooms should be covered with linoleum or painted with an acid-proof paint. Battery acid and gases will rot an unprotected wood floor quickly and may cause accidents. (55) Storage batteries may be adversely affected by extreme temperatures, either hot or cold. They should never be in the same room with rheostats, nor exposed to low temperatures through improperly placed ventilators. Projection Room Ventilation (56) Proper projection room ventilation is important