Start Over

F. H. Richardson's bluebook of projection (1942)

Record Details:

Something wrong or inaccurate about this page? Let us Know!

Thanks for helping us continually improve the quality of the Lantern search engine for all of our users! We have millions of scanned pages, so user reports are incredibly helpful for us to identify places where we can improve and update the metadata.

Please describe the issue below, and click "Submit" to send your comments to our team! If you'd prefer, you can also send us an email to mhdl@commarts.wisc.edu with your comments.




We use Optical Character Recognition (OCR) during our scanning and processing workflow to make the content of each page searchable. You can view the automatically generated text below as well as copy and paste individual pieces of text to quote in your own work.

Text recognition is never 100% accurate. Many parts of the scanned page may not be reflected in the OCR text output, including: images, page layout, certain fonts or handwriting.

TROUBLE-SHOOTING CHARTS 689 THE TROUBLE TESTS • 12. Check amplifying tube plate voltages at sockets 13. Check grid bias voltages at amplifying tube sockets 14. Using headphones or widereading volume indicator, check to find stage where hum originates 15. Visually and manually inspect trouble area for accidental grounds (including faulty insulation), loose ground contacts, faulty contacts or misplaced wiring; check or replace decoupling condensers 16. Replace doubtful sockets in trouble area 17. Resolder al trouble area contacts 18. Investigate electrical machinery in and near theatre for newly developed faults 19. Correct faulty machinery, apply hum filter to it, apply hum filter to amplifier, or change amplifier to another power circuit 20. Check filter condensers for open or leakage 21. Replace filter condensers 22. Check for grounded output voltage control resistor 23. Check for shorted or grounded choke coil 24. Check all amplifier rectifying circuits for open, grounded or shorted lines, including faulty soldered contacts and defective insulation 25. Apply Tests 20, 22, 23 and 24, above THE CONDITION FOUND Voltages normal Voltages abnormal All voltages normal All voltages abnormal One or more voltages abnormal Trouble localized Trouble cannot be localized TROUBLE FOUND Trouble not found TROUBLE CURED Hum remains TROUBLE CURED Hum remains Hum source found Trouble source not found TROUBLE CURED TROUBLE FOUND No trouble found Condenser tester not available TROUBLE CURED Hum remains TROUBLE FOUND urn remains TROUBLE FOUND Hum remains TROUBLE FOUND TROUBLE FOUND Trouble not found NEXT TEST • No. 13 No. 20 No. 14 No. 32 No. 28 No. 15 No. 25 No. 16 No. 17 No. 18 No. 19 No. 20 No. 22 No. 21 No. 22 No. 23 No. 24 No. 26