R-F LOADS and
WATTMETERS
For high power VHF and UHF applications
These Loads and Wattmeters are designed for convenient and accurate measuring of TV transmitter r-f power. The load properly terminates the r-f output of the transmitter and gives a measurement of the average r-f power. Easily installed — occupies little space. A choice of ratings is available for frequencies between 54 mc and 890 mc and for many power levels. Used by leading stations for many years.
3 KW, 54 to 216 MC
Designed for use to 5 KW of peak power. Termination type unit, supplied for operation in 54 to 21 6 mc frequency range. Water cooled. Designed for wall or rack mounting (not illustrated). Type MI-19024-A
50 KW, 54 to 216 MC
Supplied for operation in the 54 to 216 mc frequency range. Water cooled, it has an 84 KW peak power rating (not illustrated). Type MI-19191-L/H
25 KW, 54 to 216 MC
A water cooled termination type unit for operation in the 54 to 216 mc range. This unit has a 40 KW peak power capacity (shown above). Type MI-19193-L/H
1200 Watt, 54 to 216 MC
A natural air-convection-cooled portable unit. Type MI-19196-L/H. Has a peak rating of 2 KW.
25 KW, 470 to 890 MC
A column of tap water is used for power dissipation up to 40 KW on peaks in this termination type load. Type MI-19198-A2.
1 200 Watt, 470 to 890 MC
The type MI-19197 is designed with a peak power rating of 2 KW. (Companion unit to the MI-19196 unit shown at extreme left.)
7.5 KW, 54 to 216 MC
A water-cooled, termination type unit, it has a peak rating of 10 KW. Type MI-27396.
■ Specify 50 or 51.5 ohms as required for 54 to 216 mc
R-F LOADS AND WATTMETERS
Type ol Cooling Natural Air Convector Natural Air Convector Tap Water (1 GPM) Tap Water (4 GPM) Tap Water (,5.5 GPM) Water & Pumped Coolant
(10 GPM) Water & Pumped Coolant (20 GPM)
Ml Number
Ratines
Avg. Power
Usable Range
Input Imped.*
19196-L/H
54-216 mc.
1200 W
0 to 1200 W
50/51.5 ohms
19197
470-890 mc.
1200 W
0 to 1200 W
50 ohms
19024-A
54-216 mc.
3 KW
1.0 to 5 KW
50/51.5 ohms
27396
54-216 mc.
7.5 KW
1.0 to 7.5 KW
50/51.5 ohms
19198-A2
470-890 mc.
25 KW
0.1 to 25 KW
50 ohms
19193-L/H
54-216 mc.
25 KW
0 to 25 KW
50/51.5 ohms
19191-L/H
54-216 mc.
50 KW
0 to 50 KW
50/51.5 ohms
Special Loads can be supplied for other frequencies and power on a custom basis. For further particulars write to RCA, Broadcast and Television Equipment, Dept. WD-22, Building 15-5, Camden, New Jersey.