INTERNATIONAL PROJECTIONIST
March 1938
Table 1. — Classification of Cities by Requirements as to Projection-Room Size
IUBC = Uniform Building Code; NBFU=National Board of Fire Underwriters; TIC = Travelers Insurance
Company]
Minimum requirement
Number of cities
Minimum requirement
Number of cities
Total number of cities covered
186
Floor area (basis, 1 machine) — Continued.
2
Floor area (basis, 1 machine) :
1 1 2 30 46 2 1 6 2 1 1 1 20 5 4 7
2
100 square feet.
4 feet rear, 3 feet sides .
1
80 square feet,.
iVi feet rear and sides .
14
60 square feet-
2
60 square feet (UBC) _..
2 feet sides and rear.
8
48 square feet (NBFU and TIC)
8x10 feet
Sufficient to permit operator free
14
9x 9 feet.
13
8x9feet
Height of room:
9 feet
8x8feet —
1
7M x 10 feet
3
7x 9 feet, 10 inches .
8 feet .
47
7x 9 feet .'
1
6x8 feet..
7 feet (NBFU, TIC, and UBC)
6 feet
103
6x 7 feet
16
6x 6 feet -._ _.
1
6x 5 feet
No provision
14
sions of openings for projection of films Code cities in this study is low (17 and lookout or observation ports. In cities), as many of the member mustallation of sanitary facilities directly nicipalities are located in Calif, and are
connected with the room for the use of projectionists is required in only onethird of the 186 reporting cities.
Room area. — Table 1 shows the classification of the cities by requirements as to floor area and height minima of projection rooms. The floor dimensions are for the first machine in a room.
In this and the other tabulations a notation has been made in every case
below the population limit to which this investigation was restricted. Standards in excess of 50 square feet apply in 18 cities.
A lower requirement than 48 square feet exists in 20 cities; in 14 cities it is required simply that the operator shall have free movement; and in 25, where it is required that there shall be a given
cities, as far as could be ascertained, had no minimum requirements regarding floor area.
The requirement as to floor area of projection rooms is written into a number of municipal ordinances and local building codes. The greater part of the higher requirements, however, originates in State law, as in Conn., Ind., Mass., N. J., N. Y., Tenn., and Texas. Ohio requires a floor area of 5 by 6 feet; in Penn. the distance between machines and walls is specified; and in Mich, the provision is of a general nature, namely, that operators shall have sufficient room to move about freely.
The standards proposed by the N. B. of E. U. and the T. I. C. — a floor area of 48 square feet for the first machine and 24 square feet additional for each additional installation — is generally in force in the large group of cities conforming to the 48-square-feet minimum for the first machine. In other areas, the additional space requirement varies considerably but tends to be lower, with the exception of the cities subscribing to the U. B. C, where theatres must provide 50 square feet for each machine, a considerably higher standard than that in force in other cities.
Height requirements of from 7 to 9 feet in 155 cities make adequate provi
Table 2. — Classification of Cities by Requirements as to Projection-Room Doors and Other
Openings
[UBC=Uniform Building Code; TIC = Travelers Insurance Co.: NBFU=National Board of Fire Underwriters]
6 National Board of Fire Underwriters Regulations for Nitrocellulose Motion-Picture Film as recommended by the National Fire Prevention Association, effective Aug. 15, 1931. New York, 1931.
6 Safety in moving-picture theatres. Hartford, 1914.
7 Pacific Coast Building Officials Conference. Uniform Building Code, 1937 ed. Los Angeles, 1937.
number of feet at the rear and sides of where a particular standard has been tjie machine, it is not possible to state sion for the comfort of operators. In set up by agencies concerned with mak whether the net result is a smaller or the 17 cities where the lower limit is 6' ing or proposing safety standards, such larger work space than in the cities sub and less, some inconvenience must necesas the National Board of Fire Under ject t0 specific requirements. Thirteen sarily be experienced by men of greater
writers, National Electric Code, the
Pacific Coast Uniform Building Code, and the Travelers Insurance Co. In order to conserve space, initials, instead of the full name of the body referred to, have been used.
The regulations of 114 cities require that the minimum floor area for the first machine in a room shall be 48 square feet or over. This group includes cities in which the minimum area is specified in square feet and also those in which the dimensions are given in linear feet, as 6 by 8 feet (48 square feet) . These regulations conform with the standard (48 square feet) adopted by the Underwriters5 and the T. I. C.6
The U. B. C.7, adopted by 159 cities in 19 States and Hawaii, provides for a slightly larger floor area — 50 square feet. Of the 30 cities of 50,000 and over prescribing 50 square feet, 16 are subscribers to the U. B. C, the remaining subscriber (Austin, Tex.) having adopted a higher standard locally. The representation of the Uniform Building
Requirement
Number of cities
Requirement
Number of cities
Total number of cities covered „
186
Lookout ports— dimensions or area— Con.
6 3
Door-opening specifications:
66
2
3
5
2
2
2
1
1
3
1
45
13
2
22
16
1 18
2
1
5
1
1
1
1
8
1
6 28
1
1
8x 12 inches
Automatic closing, opening outward,
6x 12 inches .
21
fireproof, etc. (UBC)..
4 x 12 inches.. .
16
Size of door:
2 to 8 inches
1
3 to 5 feet x 5 feet, 10 inches
22
3x7feet —
2 feet, 8 inches x 7 feet -
No provision
27
2x7feet
Openings for projection — Specifications: Area:
144 square inches
2 feet, 6 inches x 6 feet, 8 inches—. „ 2 feet, 6 inches x 6 feet, 6 inches .
2
2 feet, 6inches x 6 feet, 6 inches, 2 exits.
120 square inches (UBC)
18
2 feet, 4 inches x 6 feet
5
2 feet x 6 feet, 6 inches —
1
2x 6 feet, 2 exits
1
2x6feet (TIC) ..
25 square inches
1
2 feet x 5 feet, 10 inches
2 square feet
1
2 feet x 5 feet, 6 inches—
Dimensions:
12x36 inches
12 x 16 inches
2x5 feet (NBFU)
No provision
1
Lookout ports— dimensions or area:
12 x 14 inches
3
2 square feet .
12 x 12 inches
22
150 square inches (UBC)
8 x 24 inches
3
144 square inches...
1
120 square inches
1
80 square inches
1
48 square inches
7
25 square inches
8 inches greatest dimension (NBFU)
12x36 inches
0
12x24 inches
36
10 x 20 inches (NBFU)
6x8 inches
9
12x16 inches
3
12 x 14 inches
1
12 x 12 inches—
14
10 x 12 inches .
26
8 x 14 inches..
28